3-4 Service Manual
Exiting Diagnostics mode
Select Exit Diagnostics to exit the Diagnostics mode. Resetting the Printer displays, the printer
performs a POR, and returns to normal mode.
REGISTRATION
Print registration makes sure the printing is printed properly aligned on the page.
The settings available are:
Bottom Margin
Top Margin
Left Margin
Right Margin
Quick Test
To set print registration:
1. Select REGISTRATION from the DIAGNOSTICS menu.
2. Select Quick Test, and press .
To print the Quick Test page:
a. Press until the appears next to Quick Test.
b. Press .
The message Quick Test Printing… appears on the display.
Retain this page to determine the changes you need to make to the margins settings.
EP SETUP
EP Defaults See “EP Defaults” on page 3-22
Fuser Temp See “Fuser Temperature (Fuser Temp)” on page 3-22
Fuser Page Count See “Fuser Page Count” on page 3-22
Warm Up Time See “Warm Up Time” on page 3-22
Transfer See “Transfer” on page 3-22
Print Contrast See “Print Contrast” on page 3-22
Charge Roll See “Charge Roll” on page 3-22
Gap Adjust See “Gap Adjust” on page 3-22
EVENT LOG
Display Log See “Display Log” on page 3-23
Print Log See “Print Log” on page 3-23
Clear Log See “Clear Log” on page 3-24
EXIT DIAGNOSTICS
Diagnostics mode tests (continued)