Toshiba e-STUDIO500P Printer User Manual


 
Repair information 4-45
High voltage power supply removal
CAUTION: There is a danger from hazardous voltage in the area of the printer where you are
working. Unplug the printer before you begin, or use caution if the printer must receive power in
order to perform the task.
1. Remove the inner paper deflector. See “Inner paper deflector assembly removal” on page 4-47.
2. Remove the right side cover. See “Right cover removal” on page 4-8.
3. Disconnect the HVPS cable from the HVPS at connector (A).
4. Disconnect the transfer roll cable (B) from the HVPS board.
Warning: Use care when disconnecting the cable from the transformer on the HVPS. The cable and
connector can be easily damaged.
A