Toshiba e-STUDIO500P Printer User Manual


 
Repair information 4-43
8. Remove the fuser cover.
Fuser transfer plate removal
1. Remove the upper paper deflector. See “Upper paper deflector assembly removal” on page 4-79.
2. Remove the transfer roll. See “Transfer roll assembly removal” on page 4-77.
3. Remove the inner paper deflector. See “Inner paper deflector assembly removal” on page 4-47.
4. Lift the left side of the fuser transfer plate (A), and move the plate to the left to clear the right side from its
mounting.
5. Remove the screw that attaches the transfer plate ground wire to the center pan.
6. Remove the fuser transfer plate.