Toshiba e-STUDIO500P Printer User Manual


 
Diagnostic information 2-21
923 .01 Fuser over temperature.
Fuser page count
between 0 and 99,999.
Short in the thermistor circuit.
Noisy thermistor signal
Fuser is actually overheating due to
hardware faults.
Go to “923.xx—Hot fuser
service check” on page 2-90.
923 .11 Fuser over temperature.
Fuser page count
between 100,000 and
199,999.
Short in the thermistor circuit.
Noisy thermistor signal
Fuser is actually overheating due to
hardware faults.
Go to “923.xx—Hot fuser
service check” on page 2-90.
923 .21 Fuser over temperature.
Fuser page count
between 200,000 and
299,999.
Short in the thermistor circuit.
Noisy thermistor signal
Fuser is actually overheating due to
hardware faults.
Go to “923.xx—Hot fuser
service check” on page 2-90.
923 .31 Fuser over temperature.
Fuser page count
between 300,000 and
399,999.
Short in the thermistor circuit.
Noisy thermistor signal
Fuser is actually overheating due to
hardware faults.
Go to “923.xx—Hot fuser
service check” on page 2-90.
923 .41 Fuser over temperature.
Fuser page count
between 400,000 and
499,999.
Short in the thermistor circuit.
Noisy thermistor signal
Fuser is actually overheating due to
hardware faults.
Go to “923.xx—Hot fuser
service check” on page 2-90.
923 .51 Fuser over temperature.
Fuser page count
stopped at 500,000 to
preserve data.
Short in the thermistor circuit.
Noisy thermistor signal
Fuser is actually overheating due to
hardware faults.
Go to “923.xx—Hot fuser
service check” on page 2-90.
923 .91 Fuser over temperature.
Fuser page count not
available.
Short in the thermistor circuit.
Noisy thermistor signal
Fuser is actually overheating due to
hardware faults.
Go to “923.xx—Hot fuser
service check” on page 2-90.
924 .01 Open thermistor check
failure. Fuser page
count between 0 and
99,999.
Noisy thermistor signal.
Intermittent connection.
Thermistor cable not connected or
thermistor actually open.
Go to “924.xx—Hot fuser
service check” on page 2-91.
924 .11 Open thermistor check
failure. Fuser page
count between 100,000
and 199,999.
Noisy thermistor signal.
Intermittent connection.
Thermistor cable not connected or
thermistor actually open.
Go to “924.xx—Hot fuser
service check” on page 2-91.
924 .21 Open thermistor check
failure. Fuser page
count between 200,000
and 299,999.
Noisy thermistor signal.
Intermittent connection.
Thermistor cable not connected or
thermistor actually open.
Go to “924.xx—Hot fuser
service check” on page 2-91.
924 .31 Open thermistor check
failure. Fuser page
count between 300,000
and 399,999.
Noisy thermistor signal.
Intermittent connection.
Thermistor cable not connected or
thermistor actually open.
Go to “924.xx—Hot fuser
service check” on page 2-91.
Service error codes (9xx.xx) (continued)
Error
code
Sub
codes
Display text Description Action