Power consumption (Watts) 500
Summit X150-48t Power
Operational voltage range 90 to 264 V
Nominal input ratings 100 to 240 V , 50/60 Hz, 1.0 A
Input current 0.6 A @ 115 V (low-line)
0.3 A @ 230 V (high-line)
Line frequency range 47 to 63 Hz
Inrush current 30 A @ 115 V, 60 A @ 230 V
Power supply cord type AC
Power supply input socket IEC 320 C14
Power cord input plug IEC 320 C13
Power cord wall plug Refer to “Selecting Power Supply Cords” on page 218.
Power supply cord gauge 18 AWG (0.75 mm
2
) up to 6 feet or 2 meters
or
16 AWG (1.0 mm
2
) over 6 feet
Efficiency 83%
Heat dissipation (BTU) 170.6
Heat dissipation (Watts) 50
Power consumption (BTU) 170.6
Power consumption (Watts) 50
Safety Standards
North American Safety of ITE UL 60950-1:2003 1st Ed., Listed Device (US)
CSA 22.2#60950-1-03 1st Ed.(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
IEEE 802.3af 6-2003 Environment A for PoE Applications
European Safety of ITE EN 60950-1:2001+A11
EN 60825-1+A2:2001 (Lasers Safety)
TUV-R GS Mark by German Notified Body
73/23/EEC Low Voltage Directive
International Safety of ITE CB Report & Certificate per IEC 60950-1:2001 Country Deviations
AS/NZX 60950-1 (Australia /New Zealand)
EMI/EMC Standards
North America EMC for ITE FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
European EMC standards EN 55022:1998 Class A
EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11
EN 61000-3-2,3 (Harmonics & Flicker)
ETSI EN 300 386:2001 (EMC Telecommunications)
89/336/EEC EMC Directive
International EMC certifications CISPR 22:1997 Class A (International Emissions)
CISPR 24:1997 Class A (International Immunity)
IEC/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15kV Air,
Criteria A
IEC/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A
IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A
IEC/EN 61000-4-5 Surge, 2kV L-L, 2kV L-G, Level 3, Criteria A
IEC/EN 61000-4-6 Conducted Immunity, 0.15-80MHz, 10V/m unmod.
RMS, Criteria A
IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25 periods,
Criteria C
Table 33: Summit X150 Series Switch Technical Specifications (Continued)