Summit X450 Series Switches
The Summit X450 series includes the following switches:
Summit X450-24t switch
Summit X450-24x switch
Table 36: Summit X450 Series Switch Technical Specifications
Physical Dimensions
Summit X450-24t switch
Summit X450-24x switch
Height: 1.73 inches (4.4 cm)
Width: 17.35 inches (44.1 cm)
Depth: 16.38 inches (41.6 cm)
Weight
Summit X450-24t switch 14 lb (6.35 kg)
Summit X450-24x switch 13.8 lb (6.26 kg)
Power
Summit switch Auto-ranging 100 V to 240 V AC, 50/60 Hz
Min voltage/associated current 1.5 A at 100 V
Max voltage/associated current 1 A at 240 V AC
Line frequency 50 to 60 Hz
Heat dissipation, Watts/BTU 160 W/546 BTU/hr
Power supply cord selection Refer to “Selecting Power Supply Cords” on page 218.
Safety Standards
North American Safety of ITE UL 60950-1:2003 1st Ed., Listed Device (US)
CSA 22.2#60950-1-03 1st Ed.(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
NOM/NYCE (Mexico)
IEEE 802.3af 6-2003 Environment A for PoE Applications
European Safety of ITE EN 60950-1:2001+A11
EN 60825-1+A2:2001 (Lasers Safety)
TUV-R GS Mark by German Notified Body
73/23/EEC Low Voltage Directive
International Safety of ITE CB Report & Certificate per IEC 60950-1:2001 Country Deviations
AS/NZX 60950-1 (Australia /New Zealand)
EMI/EMC Standards
North America EMC for ITE FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
European EMC standards EN 55022:1998 Class A
EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11
EN 61000-3-2,3 (Harmonics & Flicker)
ETSI EN 300 386:2001 (EMC Telecommunications)
89/336/EEC EMC Directive
International EMC certifications CISPR 22:1997 Class A (International Emissions)
CISPR 24:1997 Class A (International Immunity)
IEC/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15kV Air, Criteria A
IEC/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A
IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A
IEC/EN 61000-4-5 Surge, 2kV, 4kV, Criteria A
IEC/EN 61000-4-6 Conducted Immunity, 0.15-80MHz, 10V/m unmod. RMS,
Criteria A
IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25 periods,
Criteria C