M208 SPECIFICATIONS: Hardware Specifications 189
The seven-stage power-on self test performs diagnostics on the
processor, RAM, ROM, EEPROM, serial ports, parallel port, and
network interface. The STAT, ERR, and NET LEDs indicate
which test is currently in progress.
Run Mode is the normal operating state of the M208. Auto-Reset
mode is entered when the watchdog timer is triggered and the
Print Server has reset itself. In either mode, the STAT LED
flashes differently depending on whether the unit’s IP address is
configured and COM1 monitor is active.
Table 11: Run and Auto-Reset Mode Description
STAT Rate Indicates
Flashes On once per second Normal Mode, IP
address configured
Flashes On 2.5 times per second Monitor Mode, IP
address not configured
Flashes Off once per second Normal Mode, IP
address configured
Flashes Off 2.5 times per second Monitor or Download
Mode, IP address not
configured
Flashes off once per 2 seconds Download Mode, IP
address configured
Power-on Self Test
Run and Auto-Reset