Maintenance - Vehicle Mounted Devices
Check the vehicle mounting hardware frequently and re-tighten if necessary.
If the vehicle mounting hardware and connections become broken, loose or cracked, the assembly must be taken out of service
and replaced. Contact Technical Assistance (page 9-1) for help.
Cleaning
Do not use paper towels or harsh-chemical-based cleaning fluids since they may result in damage to the Thor VM2 surfaces,
cables, connectors and mounting hardware.
Use a clean soft cloth to wipe any dirt, moisture or grease from the Thor VM2, connectors, cables or the vehicle mounting hard-
ware. Do not use any liquid to clean the Thor VM2, or connectors. Spray or dampen the cleaning cloth with the cleaning liquid.
If possible, clean only those areas which are soiled. Lint/particulates can be removed with clean, filtered canned air.
Place Thor VM2 in the Dock
1. Locate the notch on the upper rear of the Thor VM2.
2. Slide this notch over the top lip of the dock. Slide the Thor VM2 from side to side on the dock to make sure it fully engages
on the lip of the dock. If the Thor VM2 cannot be slid side to side, the lip is engaged.
3. Pull the quick release lever on the Thor VM2 down and push the Thor VM2 against the dock.
4. Release the quick release lever. The quick release lever catches the lower lip on the dock and secures the Thor VM2 to the
dock.
5. If necessary, adjust the viewing angle of the Thor VM2.
When the Thor VM2 is placed in the dock, the following may happen:
If the Thor VM2 is off and power is connected to the dock, the Thor VM2 may boot when placed in the dock. The behavior
depends on the Power Scheme selected. See Ignition Control/Ignition On (page 5-26) and Auto-On (page 5-30).
If the Thor VM2 is on and power is connected to the dock, the Thor VM2 power management timers may change when the
Thor VM2 is placed in the dock. See Power Schemes (page 5-22).
When the Thor VM2 is removed from the dock, the following may happen:
If the Thor VM2 is on and power is connected to the dock, the Thor VM2 power management timers may change when the
Thor VM2 is placed in the dock. See Power Schemes (page 5-22).
Back of Thor VM2 Front of Quick Mount Smart Dock
Notch on
Thor VM2
Release Lever
Upper Lip on Dock
Lower Lip on Dock