Appendix D Register-Level Programming
National Instruments Corporation D-17 PC-LPM-16/PnP User Manual
A/D Clear Register
Write to this register to reset the ADC. This operation clears the data FIFO. All error bits
in the Status Register are cleared as well. For the PC-LPM-16 (non PnP only), writing to
this register clears the data FIFO and loads a single conversion into the FIFO. After
writing to the A/D Clear Register, it is necessary to read both the High- and Low-Byte
FIFOs. The data that is read back should be ignored.
Address:
Base address + 01 (hex)
Type:
Write-only
Word Size:
8-bit
Bit Map:
Not applicable, no bits used