CHAPTER 5 ND-71548 (E)
Page 344
Issue 2
INSTALLATION TEST PROCEDURE
NAP-200-039
Sheet 1/1
Connection Test-Paging Trunk for Paging
Access Service
START
Dial the paging access code Station A/ATTCON dials the paging access code and hears
CRBT (Continuous Ringback Tone).
In about 1 second, CRBT stops.
Speaker Paging Check whether speaker paging is possible after CRBT has
stopped.
Release Station A goes on-hook or the ATTCON depresses
CANCEL key.
END
LCStation A
ATTCON
PGT
AMP SP