INSTALLATION TEST PROCEDURE
NAP-200-052
Sheet 2/3
IPTRK (IP Trunk Card for CCIS)
Connection Test
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
The following explains how to solve the problems. When the problem can not be solved by the step, go to
the next step.
1) Remove and insert the circuit card, and make sure that the sub card is stable when used.
2) Make sure office data and mount location data by using ACRD/ACTK command.
3) Initialize the circuit card.
4) Re-download the firmware into the circuit card by using CD.
5) Replace the circuit card.
START
[1] Confirm that OPE lamp (*A) on IPTRK is lighting.
The following explains how to solve the problems. When the problem can not be solved by the step, go to
the next step.
1) Remove and insert the circuit card, and make sure that the sub card is stable when used.
2) Initialize the circuit card.
3) Re-download the firmware into the circuit card by using CD.
4) Replace the circuit card.
[2] Confirm that VC0 lamp (*B) on IPTRK is lighting, which indicates that voice compression is active.
When sub card is installed, confirm VC1 lamp (*B) on the circuit card is lighting.
When IP-LINK is off : Make sure F-LAN connectors and external LAN cables are installed.
- Check LAN cables (straight) are stable in the connector.
- Check LAN cables by a tester or other equipment.
- Check the normality of network equipment (SW HUB and Router) and HUB circuit card.
[3] Confirm that IP-LINK lamp (*C) on IPTRK is lighting green, which indicates that the circuit card is
connected to the network physically.
YES
NO
YES
NO
YES
NO
A