Using the BayStack 350 10/100/1000 Series Switch
3-28
309979-A Rev 00
Gigabit Ports and BayStack 410-24T Switch Ports Restriction
Gigabit ports and the BayStack 410-24T switch ports do not have the ability to
assign incoming untagged frames to a protocol-based VLAN. To allow these types
of ports to participate in protocol-based VLANs, you must set the following
values for these ports:
1.
Set the Tagging field value in the VLAN Port Configuration screen to
Tagged Trunk.
2.
Set the Filter Untagged Frames field value to Yes.
VLAN Port Configuration
The VLAN Port Configuration screen (Figure 3-10
) allows you to configure
specified switch ports with the appropriate PVID/VLAN association that enables
the creation of VLAN broadcast domains (see “Shared Servers” on page 1-29 for
more information about setting up VLAN broadcast domains).
You can configure specified switch ports to filter (discard) all received tagged
frames, untagged frames, or unregistered frames (see “IEEE 802.1Q Tagging” on
page 1-21).
You can also prioritize the order in which the switch forwards packets, on a
per-port basis (see “IEEE 802.1p Prioritizing” on page 1-10).
Choose VLAN Port Configuration (or press c) from the VLAN Configuration
Menu screen to open the VLAN Port Configuration screen.