Nortel Networks 350 Switch User Manual


 
Using the BayStack 350 10/100/1000 Series Switch
1-66
309979-A Rev 00
In the configuration example shown in Figure 1-44 on page 1-65, the designated
monitor port (port 23) can be set to monitor traffic in any of the following modes:
Monitor all traffic received by port X.
Monitor all traffic transmitted by port X.
Monitor all traffic received and transmitted by port X.
Monitor all traffic received by port X or transmitted by port Y.
Monitor all traffic received by port X (destined to port Y) and then
transmitted by port Y.
Monitor all traffic received/transmitted by port X and received/transmitted
by port Y (conversations between port X and port Y).
As shown in the Port Mirroring Configuration screen example (Figure 1-45
), a
user has designated port 23 as the Monitor Port for ports 24 and 25 in switch S1.
The Monitoring Mode field [ - > Port X or Port Y - > ] indicates that all traffic
received by port X or all traffic transmitted by port Y is currently being monitored
by the StackProbe attached to Monitor Port 23.
The screen data displayed at the bottom of the screen shows the currently active
port mirroring configuration.