Nortel Networks 350 Switch User Manual


 
Using the BayStack 350 10/100/1000 Series Switch
1-54
309979-A Rev 00
Trunk Configuration Screen for Switch S3
As shown in Figure 1-35
on page 1-48, switch S3 is set up with one trunk
configuration (T4). This trunk connects directly to switch S1.
As in the previous screen examples, to set up an inter-switch trunk configuration
choose MultiLink Trunk Configuration from the MultiLink Trunk Configuration
Menu screen.
Figure 1-39
shows the MultiLink Trunk Configuration screen for switch S3.
Figure 1-39. MultiLink Trunk Configuration Screen for Switch S3
Switch S3 is configured as follows:
Trunk (read only) indicates the trunks (1 to 6) that correspond to the switch
ports specified in the Trunk Members fields.
Trunk Members indicates the ports that can be configured, in each row, to
create the corresponding trunk:
Ports 1 and 3 are assigned as trunk members of trunk 1.
MultiLink Trunk Configuration
Trunk Trunk Members STP Learning Trunk Mode Trunk Status
----- ---------------------------- ------------ --------------- ------------
1 [ 1 ][ 3 ][ ][ ] [ Normal ] Basic [ Enabled ]
2 [ ][ ][ ][ ] [ Normal ] Basic [ Disabled ]
3 [ ][ ][ ][ ] [ Normal ] Basic [ Disabled ]
4 [ ][ ][ ][ ] [ Normal ] Basic [ Disabled ]
5 [ ][ ][ ][ ] [ Normal ] Basic [ Disabled ]
6 [ ][ ][ ][ ] [ Normal ] Basic [ Disabled ]
Trunk Trunk Name
----- ------------------
1 [ S3:T4 to S1 ]
2 [ Trunk #2 ]
3 [ Trunk #3 ]
4 [ Trunk #4 ]
5 [ Trunk #5 ]
6 [ Trunk #6 ]
Use space bar to display choices, press <Return> or <Enter> to select choice.