Using the BayStack 350 10/100/1000 Series Switch
1-50
309979-A Rev 00
The MultiLink Trunk Configuration screen opens (Figure 1-37).
Figure 1-37. MultiLink Trunk Configuration Screen for Switch S1
Switch S1 is configured as follows:
• Trunk (read only) indicates the trunks (1 to 6) that correspond to the switch
ports specified in the Trunk Members fields.
• Trunk Members indicates the ports that can be configured, in each row, to
create the corresponding trunk:
-- Ports 15, 17, 19, and 21 are assigned as trunk members of trunk 1.
-- Ports 25 and 26 are assigned as trunk members of trunk 2.
-- Ports 2 and 4 are assigned as trunk members of trunk 3.
-- Ports 14 and 16 are assigned as trunk members of trunk 4.
-- Ports 22 and 24 are assigned as trunk members of trunk 5.
MultiLink Trunk Configuration
Trunk Trunk Members STP Learning Trunk Mode Trunk Status
----- ---------------------------- ------------ --------------- ------------
1 [ 15 ][ 17 ][ 19 ][ 21 ] [ Normal ] Basic [ Enabled ]
2 [ 25 ][ 26 ][ ][ ] [ Normal ] Basic [ Enabled ]
3 [ 2 ][ 4 ][ ][ ] [ Normal ] Basic [ Enabled ]
4 [ 14 ][ 16 ][ ][ ] [ Normal ] Basic [ Enabled ]
5 [ 22 ][ 24 ][ ][ ] [ Fast ] Basic [ Enabled ]
6 [ ][ ][ ][ ] [ Disabled ] Basic [ Disabled ]
Trunk Trunk Name
----- -------------------
1 [ S1:T1 to FS2 ]
2 [ S1:T2 to S2 ]
3 [ S1:T3 to S2 ]
4 [ S1:T4 to S3 ]
5 [ S1:T5 to S4 ]
6 [ Trunk #6 ]
Use space bar to display choices, press <Return> or <Enter> to select choice.
Press Ctrl-R to return to previous menu. Press Ctrl-C to return to Main Menu.