Nortel Networks 350 Switch User Manual


 
Using the BayStack 350 10/100/1000 Series Switch
C-12
309979-A Rev 00
3.
Insert the MDA into the Uplink Module card guides (Figure C-5).
Make sure the MDA slides in on the card guides. Failure to align the MDA to
the card guides could damage the pins.
Figure C-5. Installing an MDA
4.
Press the MDA
firmly
into the Uplink Module slot.
Be sure that the MDA is fully seated into the mating connector.
5.
Secure the MDA by tightening the thumb screws on the MDA front panel.
6.
Attach devices to the MDA ports (see “Attaching Devices to the BayStack
350 Switch” on page 2-7).
After connecting the port cables, continue to follow the instructions to connect
power and verify the installation.
Note:
If you are replacing an installed MDA with another type of MDA, see
Replacing an MDA with a Different Model” on C-13.
Note:
The IEEE 802.3u specification requires that all ports operating at 100
Mb/s use only Category 5 unshielded twisted pair (UTP) cabling.
BS35046A