Nortel Networks 350 Switch User Manual


 
Using the Console Interface
309979-A Rev 00
3-15
Table 3-4. System Characteristics Screen Fields
Field Description
Operation Mode
Read-only field that indicates the operating mode of the switch.
MAC Address
The MAC address of the BayStack 350 switch.
Reset Count
A read-only field that indicates the number of resets since the operational firmware
was first loaded on the switch.
Default Value: 1
Range: 0 to 2
32
-1
Last Reset Type
A read-only field that indicates the last type of reset.
Default Value: Power Cycle
Range: Power Cycle, Software Download, Management Reset,
Management Factory Reset
Power Status
A read-only field that indicates the current power source.
Default Value: Primary Power
Local MDA Type
A read-only field that indicates the MDA type that is configured in this switch.
sysDescr
A read-only field that specifies the hardware and software version.
sysObjectID
A read-only field that provides a unique identification of the switch, which contains the
vendor’s private enterprise number.
sysUpTime
A read-only field that shows the length of time since the last reset. This field is
updated when the screen is redisplayed.
sysServices
A read-only field that indicates the switch’s physical and data link layer functionality.
sysContact
The name and phone number of the person responsible for the switch.
Default Value Zero-length string
Range: Any ASCII string of up to 56 printable characters
1
1 Although this field can be set to up to 255 characters from a Network Management Station (NMS), only 56 characters
are displayed on the console terminal.
sysName
A name that uniquely identifies the switch.
Default Value: Zero-length string
Range: Any ASCII string of up to 56 printable characters
1
sysLocation
The physical location of the switch.
Default Value: Zero-length string
Range: Any ASCII string of up to 56 printable characters