Nortel Networks 350 Switch User Manual


 
Using the BayStack 350 10/100/1000 Series Switch
3-72
309979-A Rev 00
Figure 3-31. Spanning Tree Port Configuration Screen (2 of 2)
Table 3-28 describes the Spanning Tree Port Configuration screen fields.
Table 3-28. Spanning Tree Port Configuration Screen Fields
Field Description
Port
Indicates the switch port numbers that correspond to the field settings in that row of the
screen (for example, the field settings in row 2 apply to switch port 2). Note that the
settings in the All row (bottom row) affect all switch ports.
Trunk
The read-only data displayed in this column indicates the trunks that correspond to the
switch ports specified in the Trunk Members fields of the Trunk Configuration screen (see
MultiLink Trunk Configuration
” on page 3-39).
(continued)
Spanning Tree Port Configuration
Port Trunk Participation Priority Path Cost State
---- ----- ------------------- -------- --------- ----------
15 [ Normal Learning ] 128 5 Forwarding
16 [ Normal Learning ] 128 5 Forwarding
17 1 [ Normal Learning ] 128 10 Forwarding
18 [ Normal Learning ] 128 10 Forwarding
19 4 [ Normal Learning ] 128 10 Forwarding
20 4 [ Normal Learning ] 128 10 Forwarding
21 [ Normal Learning ] 128 10 Forwarding
22 5 [ Normal Learning ] 128 10 Forwarding
23 5 [ Normal Learning ] 128 10 Forwarding
24 [ Normal Learning ] 128 10 Forwarding
25 2 [ Normal Learning ] 128 10 Forwarding
26 2 [ Normal Learning ] 128 10 Forwarding
27 [ Normal Learning ] 128 10 Forwarding
28 [ Normal Learning ] 128 10 Forwarding
All [ Normal Learning ]
Press Ctrl-P to display choices for ports 1-14.
Use space bar to display choices, press <Return> or <Enter> to select choice.