129
The camera image is dim. Dust may be sticking on the camera
lens.
Remove the dust from the camera lens.
The camera’s lens focus may not be
proper.
Press the FOCUS NEAR/ FAR buttons
to adjust the lens focus. If the camera
supports auto focus, press these but-
tons simultaneously. The lens focus can
be adjusted automatically.
The camera’s cable compensation set-
ting may not be proper.
Open 710 COMPENSATION/VD2/DATA
(refer to p. 60) or the Cable Compensa-
tion/VD2 window (refer to p. 78) to con-
firm the setting.
The camera is not operable. The camera may not have been select-
ed.
Select the camera again. (Refer to p.
91.)
The camera may not support the func-
tion you try to execute.
Confirm whether the camera supports
the function. (Refer to the camera's
operating instructions.)
The camera's cable setting may wrong. Open 710 COMPENSATION/VD2/DATA
(refer to p. 60) or the Cable
Compensation/VD2/DATA (refer to p.
78) window to confirm the setting. If the
camera’s DATA is set to OFF, the RS-
485 cameras will not be operable.
The data port setting may wrong. Open the Data Port window (refer to p.
81) and confirm the setting.
When the BUSY indicator is lighting on
the system controller, a higher-priority
operator has selected the camera.
• Select another camera.
• Wait until a higher-priority operator fin-
ishes controlling the camera.
While the PROHIBITED indicator is
lighting on the system controller, you
are prohibited to control the camera.
Open the Operator Registration window
(refer to p. 75) and reconfigure the set-
ting.
OSD items (Clock, Camera title, Monitor
status, Event) overlap one another.
• Turn off an overlapping item. (Refer to
p. 99.)
• Move OSD items. (Refer to p. 99.)
• Change the area title display position
through the camera’s setup menu.
(Refer to the camera’s operating
instructions.)
Tour/group sequence is not activated. The tour/group sequence setting may
be wrong.
Open 300 SEQUENCE (refer to p. 55),
the Tour Sequence (refer to p. 68) or
Group Sequence (p. 69) window and
reconfigure the setting.
The setting has not been put from the
PC to the unit.
Put the configuration data to the unit
again after the configuration. (Refer to
p. 67 Put a File to SX150.)
When the PROHIBITED indicator is
lighting on the system controller, you
are prohibited to control the camera.
Open 800 OPERATOR REGISTRATION
(refer to p. 62) or the Operator
Registration window (refer to p. 75) and
reconfigure the setting.
Problem Check item Remedy