47
■ Connection with the PC
1. Conform the communication speed (SERIAL PORT
SPEED) parameter in SETUP MENU to that of the PC.
2. Connect the matrix switcher's serial port to that of the
PC with the 9-pin D-sub cable.
Notes:
• The following parameters are fixed.
Data bit: 8 bits
Parity check: none
Stop bit: 1 bit
• Refer to Cable Specifications in this page for details on
cables.
● Cable Specifications
1
2
3
4
5
6
7
8
Frame
1
2
3
4
5
6
7
8
Frame
Shield
PC WJ-SX150
SERIAL
Personal Computer Matrix Switcher
D-sub9
D-sub9
or
D-sub25
■ Time Adjustment with an External
Equipment
The specified external devices can output the time adjust-
ing signal to the matrix switcher.
This signal can adjust the time by up to ± 30 seconds every
hour.
To use this function, it is necessary to assign one of the
alarm input terminals (pin # 1 to 16) to the time adjusting
terminal.
SETUP MENU or WJ-SX150 Administrator Console can
assign the signal.
● Master Clock Connection Example for Time
Adjustment
Connect the matrix switcher's time adjusting terminal to
those of the master clock with the twisted pair cable.
The figure below shows the case in which Alarm Input 16 is
assigned as the time adjusting terminal.
Note: A master clock with N.O. (Normally Open alarm con-
tact)-type output is connectable.
12
6
39
Master clock
Matrix Switcher
ALARM
Pin #21
Pin #22
GND