75
■ Operator Registration
This window configures the parameters of each operator:
the ID, password, level, priority and camera access.
Note: Before configuring this window, check on the
restrict level of each operation in the Level Table
window.
● How to Display
To display this window, click on the (Operator
Registration) button in the main window (p. 65).
● Parameters
• Operator Number
This box displays a list of registered operators.
1-6: These are operator numbers who are registered as
the factory default setting. Operator Number 1 can-
not be deleted.
Timer: This operator is used for the priority change of a
timer event. When the timer event's priority is higher
than that of an operator, the event is valid. When an
operator's priority is higher than that of a timer
event, the event is invalid. This operator cannot be
deleted.
• Add Operator Number
This drop-down menu is used for the new operator number
selection.
• Operator Group
This group configures each operator's password, level and
priority.
ID: Enter an operator's ID. From 1 to 99999 are avail-
able.
Password: Enter a password. From 1 to 99999 are
available.
Level: Select 1, 2 or 3.
Priority: Select the operator's priority from 1 (highest)
to 16 (lowest).
• Camera Access Group
This group configures the camera operation coverage of
each operator.
Click on each camera's checkboxes and determine the
available operation.
1 (View & Control): The operator can display the cam-
era image on the monitor and control panning/tilt-
ing.
2 (View Only): The operator can display the camera
image on the monitor, but cannot control the pan-
ning/tilting.
3 (Prohibited): The operator can neither display the
camera image on the monitor nor control the pan-
ning/tilting.
(Add) button
Adds a new operator to WJ-SX150 Administrator Console.
(Edit) button
The registered parameters become editable by clicking on
this button after selecting the operator number.
(Delete) button
Deletes an operator from WJ-SX150 Administrator Console
after you select the operator.
(OK) button
Saves the configuration and closes the Operator
Registration window.