Panasonic WJ-SX 150 Network Router User Manual


 
75
Operator Registration
This window configures the parameters of each operator:
the ID, password, level, priority and camera access.
Note: Before configuring this window, check on the
restrict level of each operation in the Level Table
window.
How to Display
To display this window, click on the (Operator
Registration) button in the main window (p. 65).
Parameters
• Operator Number
This box displays a list of registered operators.
1-6: These are operator numbers who are registered as
the factory default setting. Operator Number 1 can-
not be deleted.
Timer: This operator is used for the priority change of a
timer event. When the timer event's priority is higher
than that of an operator, the event is valid. When an
operator's priority is higher than that of a timer
event, the event is invalid. This operator cannot be
deleted.
• Add Operator Number
This drop-down menu is used for the new operator number
selection.
• Operator Group
This group configures each operator's password, level and
priority.
ID: Enter an operator's ID. From 1 to 99999 are avail-
able.
Password: Enter a password. From 1 to 99999 are
available.
Level: Select 1, 2 or 3.
Priority: Select the operator's priority from 1 (highest)
to 16 (lowest).
• Camera Access Group
This group configures the camera operation coverage of
each operator.
Click on each camera's checkboxes and determine the
available operation.
1 (View & Control): The operator can display the cam-
era image on the monitor and control panning/tilt-
ing.
2 (View Only): The operator can display the camera
image on the monitor, but cannot control the pan-
ning/tilting.
3 (Prohibited): The operator can neither display the
camera image on the monitor nor control the pan-
ning/tilting.
(Add) button
Adds a new operator to WJ-SX150 Administrator Console.
(Edit) button
The registered parameters become editable by clicking on
this button after selecting the operator number.
(Delete) button
Deletes an operator from WJ-SX150 Administrator Console
after you select the operator.
(OK) button
Saves the configuration and closes the Operator
Registration window.