62
• CAMERA CLEANING
ON: Activates the manual cleaning for the cameras.
OFF: Deactivates the manual cleaning.
When you set CAMERA CLEANING to ON and exit from the
SETUP MENU, camera cleaning will start.
The factory default setting is OFF.
Notes:
• When the camera cleaning is active, cleaning will begin
from CAM 1 in numerical order.
• Surveillance is impossible during the cleaning.
• The cleaning cannot be stopped after it is started.
• Refer to pp. 38 and 39 for details on RS-485 or PS·Data
connections.
• The camera address needs to be corresponding with
the camera number.
■ OPERATOR REGISTRATION
● How to Display
To display this menu on the monitor, move the cursor to
800 OPERATOR REGISTRATION in SETUP MENU by mov-
ing the joystick to ▼.Then, press the CAM (SET) button. The
submenu appears on the monitor.
● Parameters
Move the joystick to move the cursor.
Press the NEXT or PREV button to select the desired para-
meters.
Press the numeric button(s) to enter a number.
• OPERATOR NO.
This stands for an operator number. When you enter the
number by pressing the NEXT, PREV or numeric button(s),
this menu will display the associated operator's information.
1 to 16 is available.
• ID
This stands for an operator ID. 1 to 99999 is available.
• PASSWORD
This stands for an operator's password. 1 to 99999 is avail-
able. The password will be displayed as "*" on the monitor.
800 OPERATOR REGISTRATION
OPERATOR NO.=01 ID =150
PASSWORD=*****
PRIORITY=1
LEVEL =1
CAM01=VIEW&CONTROL CAM09=VIEW&CONTROL
CAM02=VIEW&CONTROL CAM10=VIEW&CONTROL
CAM03=VIEW&CONTROL CAM11=VIEW&CONTROL
CAM04=VIEW&CONTROL CAM12=VIEW&CONTROL
CAM05=VIEW&CONTROL CAM13=VIEW&CONTROL
CAM06=VIEW&CONTROL CAM14=VIEW&CONTROL
CAM07=VIEW&CONTROL CAM15=VIEW&CONTROL
CAM08=VIEW&CONTROL CAM16=VIEW&CONTROL
• PRIORITY
This stands for an operator's priority. 1 to 16 is available.
(Refer to p. 14 for details on Priority Lock.)
• LEVEL
This stands for an operator's restrict level. It is configurable
through Level Table (refer to p. 76) of WJ-SX150
Administrator Console what kind of restriction is given to the
operator. 1 to 3 is available.
• CAM 01 to 16:
These stand for an operator's camera operation coverage.
The following are the parameters.
VIEW & CONTROL: The operator can display the
camera image on the monitor and control pan-
ning/tilting.
VIEW ONLY: The operator can display the camera
image on the monitor, but cannot control the
panning/tilting.
PROHIBITED: The operator can neither display the
camera image on the monitor nor control the
panning/tilting.
The following is the factory default setting of this menu.
Note: When you enter an invalid number, the parameter will
return to the state before your numerical entry.
■ MULTIPLEXER
● How to Display
This menu will appear only when the Multiplexer board
is installed in the unit. To display this menu on the moni-
tor, move the cursor to 900 MULTIPLEXER in SETUP
MENU by moving the joystick to D or C. Then, press
the CAM (SET) button. The submenu appears monitor.
6
OPERATOR NO. ID PASSWORD LEVEL PRIORITY
1 150 150 1 1
2112345 1 2
3 100 100 1 3
4 101 101 1 4
5 102 102 2 5
6 103
103 3
CAM 1 to 16 = VIEW & CONTROL (for OPERATOR NO. 1 to
6
900 MULTIPLEXER
VCR REC MODE
910 ALARM EXT.
920 NORMAL EXT.
930 DYNAMIC REC OFF
940 DUMMY BLACK 0FF
950 CAM SW LOSS ON