Multiplexer Mode
How to Display
Note: This window can be displayed only when “Yes” is
selected in the Recorder window. (Refer to p. 66.)
Parameters
To display this window, click on the (Multiplexer
Mode) button in the main window (p. 65.)
• Multi Monitor Out Group
Still Display: Select the desired setting by clicking on
the drop-down menu.
ON: Still picture is available during the multiscreen dis-
play.
OFF: Still picture is not available during the multiscreen
display.
The factory default setting is ON.
Border Color: Select the desired setting by clicking on
the drop-down menu. This setting will determine the
color of the border which separates each multi-
screen segment.
WHITE: The border will be displayed in white.
GRAY: The border will be displayed in gray.
BLACK: The border will be displayed in black.
OFF: No border will be displayed.
The factory default setting is WHITE.
Quad Shift: Select the desired setting by clicking on
the drop-down menu.
ON: Camera images are displayed in 4 multiscreen
segments (quad) and switched as follows:
4A = Page 1 of the quad (Camera 1, 2, 3 and 4)
4B = Page 2 of the quad (Camera 5, 6, 7 and 8)
4C = Page 3 of the quad (Camera 9, 10, 11 and
12)
4D = Page 4 of the quad (Camera 13, 14, 15 and
16)
OFF: Quad is unavailable.
The factory default setting is OFF.
Secret View: Select the desired setting by clicking on
the drop-down menu.
ON: The drop-down menu becomes also active so that
you can select the desired monitor among MON 1
to 4. For example, when you select MON 1, other
operators, whose priority is lower than you, cannot
view the monitor (secret view).
OFF: Secret view function is unavailable.
The factory default setting is OFF.
Sequence Mode: Select the sequence type by clicking
on the radio button.
Quad: Multiplexer sequence is activated. The monitor
display will be changed as 4A 4B 4C 4D.
3+1: Images are displayed in 4 multiscreens, and the
images of Camera 4 to 16 are displayed in the
sequence mode, at the right bottom of the monitor.
The images of Camera 1 to 3 are fixed. (Refer to the
left-side illustration in p. 19.)
8+1: Images are displayed in 9 multiscreens, and the
images of Camera 9 to 16 are displayed in the
sequence mode, at the right bottom of the monitor.
The images of Camera 1 to 8 are fixed. (Refer to the
right-side illustration in p. 19.)
The factory default setting is Quad.
Dwell: The dwell time of the selected sequence mode
is selectable. 2S to 30S is available.
The factory default setting is 2S.
• REC OUT Group
Title Display: Select the desired setting by clicking on
the drop-down menu.
ON: The camera title is displayed on the recorded
image.
OFF: The camera title is not displayed on the recorded
image.
The factory default setting is ON.
Clock Display: Select the desired setting by clicking on
the drop-down menu.
ON: The date and time are displayed on the recorded
image.
OFF: The date and time are not displayed on the
recorded image.
The factory default setting is ON.
Normal Group
REC Mode: Select the desired setting by clicking on
the radio button.
EXT: Select this to gen-lock the unit during the normal
recording.
INT: Select this if the asynchronous unit is connected to
the unit. When it is activated, the drop-down menu
becomes also active so that you can select the
desired normal recording rate. 002, 004 to 255
(field) are selectable.
The factory default setting is EXT.