82
■ Multiplexer Mode
● How to Display
Note: This window can be displayed only when “Yes” is
selected in the Recorder window. (Refer to p. 66.)
● Parameters
To display this window, click on the (Multiplexer
Mode) button in the main window (p. 65.)
• Multi Monitor Out Group
Still Display: Select the desired setting by clicking on
the drop-down menu.
ON: Still picture is available during the multiscreen dis-
play.
OFF: Still picture is not available during the multiscreen
display.
The factory default setting is ON.
Border Color: Select the desired setting by clicking on
the drop-down menu. This setting will determine the
color of the border which separates each multi-
screen segment.
WHITE: The border will be displayed in white.
GRAY: The border will be displayed in gray.
BLACK: The border will be displayed in black.
OFF: No border will be displayed.
The factory default setting is WHITE.
Quad Shift: Select the desired setting by clicking on
the drop-down menu.
ON: Camera images are displayed in 4 multiscreen
segments (quad) and switched as follows:
4A = Page 1 of the quad (Camera 1, 2, 3 and 4)
4B = Page 2 of the quad (Camera 5, 6, 7 and 8)
4C = Page 3 of the quad (Camera 9, 10, 11 and
12)
4D = Page 4 of the quad (Camera 13, 14, 15 and
16)
OFF: Quad is unavailable.
The factory default setting is OFF.
Secret View: Select the desired setting by clicking on
the drop-down menu.
ON: The drop-down menu becomes also active so that
you can select the desired monitor among MON 1
to 4. For example, when you select MON 1, other
operators, whose priority is lower than you, cannot
view the monitor (secret view).
OFF: Secret view function is unavailable.
The factory default setting is OFF.
Sequence Mode: Select the sequence type by clicking
on the radio button.
Quad: Multiplexer sequence is activated. The monitor
display will be changed as 4A → 4B → 4C → 4D.
3+1: Images are displayed in 4 multiscreens, and the
images of Camera 4 to 16 are displayed in the
sequence mode, at the right bottom of the monitor.
The images of Camera 1 to 3 are fixed. (Refer to the
left-side illustration in p. 19.)
8+1: Images are displayed in 9 multiscreens, and the
images of Camera 9 to 16 are displayed in the
sequence mode, at the right bottom of the monitor.
The images of Camera 1 to 8 are fixed. (Refer to the
right-side illustration in p. 19.)
The factory default setting is Quad.
Dwell: The dwell time of the selected sequence mode
is selectable. 2S to 30S is available.
The factory default setting is 2S.
• REC OUT Group
Title Display: Select the desired setting by clicking on
the drop-down menu.
ON: The camera title is displayed on the recorded
image.
OFF: The camera title is not displayed on the recorded
image.
The factory default setting is ON.
Clock Display: Select the desired setting by clicking on
the drop-down menu.
ON: The date and time are displayed on the recorded
image.
OFF: The date and time are not displayed on the
recorded image.
The factory default setting is ON.
Normal Group
REC Mode: Select the desired setting by clicking on
the radio button.
EXT: Select this to gen-lock the unit during the normal
recording.
INT: Select this if the asynchronous unit is connected to
the unit. When it is activated, the drop-down menu
becomes also active so that you can select the
desired normal recording rate. 002, 004 to 255
(field) are selectable.
The factory default setting is EXT.