133
Pausing sequence
(PAUSE)
Stopping sequence
(STOP)
Sequence increment
(NEXT)
Sequence decrement
(PREV)
Transmission command toggles priority lock
ON or OFF.
mm=Monitor No.
n=0 (OFF)
n=1 (ON)
Starting tour sequence
■ Command Table
Item Response (ASCII) Parameter (ASCII)
Log-in CMD:Wnnnnn-ppppp ANS:WOK (When OK)
ANS:WNG (When NG)
nnnnn= Operator number
ppppp= Password
Log-out CMD:H00LG ANS:H00LG
Monitor Selection CMD:HmmMS ANS:HmmMS
mm=Monitor No.
Camera Selection
CMD:HmmCScc
CMD:HmmCS+1
CMD:HmmCS-1
ANS:HmmCScc
ANS:HmmCS+1
ANS:HmmCS-1
mm=Monitor No.
cc=Camera No.
+1=To the next camera (Next)
-1=To the previous camera (Prev)
CMD:HmmSTnn
ANS:HmmSTnn
Starting group sequence CMD:HmmSGn ANS:HmmSGn
mm=Monitor No.
n=Group sequence No.
CMD:HmmSP ANS:HmmSPn
mm=Monitor No.
n=0 (SEQUENCE), 1 (PAUSE)
ANS:HmmSO
mm=Monitor No.
CMD:HmmSI ANS:HmmSI
mm=Monitor No.
Available only during sequence pause
CMD:HmmSD
ANS:HmmSD
mm=Monitor No.
Available only during sequence pause
Priority lock CMD:HmmPR ANS:HmmPRn
CMD:HmmSO
Basic Operation
Transmission Command
(ASCII)
OSD display ON / OFF
or
Moving OSD display posi-
tion
CMD:Hmmss(o) ANS:HmmALn Transmission command toggles OSD display
ON or OFF.
Use (o) parameter when moving OSD dis-
play position.
mm=Monitor No.
ss=AL All OSD items ON/OFF
ss=TM Time & date ON/OFF
ss=TL Camera title ON/OFF
ss=TE Event ON/OFF
ss=TO Monitor status ON/OFF
o=U Moving upward
o=D Moving downward
o=L Moving leftward
o=R Moving rightward
n=0 Displayed
n=1 Not displayed
History or status display
ON/OFF
CMD: Hmmss ANS: Hmmssn mm=Monitor No.
ss=DA Alarm history ON/OFF
ss=DV Video loss history ON/OFF
ss=DS System status ON/OFF
n=0 Displayed
n=1 Not displayed
mm=Monitor No.
nn=Tour sequence No.
nn=00 Recorder sequence ON when the
recorder is selected.