56
TOUR NO: Press the NEXT or PREV button to select the
tour number. Or press the numeric button(s) to
enter a number.
STEP: This stands for a tour sequence step.
CAM: This stands for a camera number. CAM 0 to 16 is
selectable. CAM 0 deactivates the sequence step.
The factory default setting is assigned to each step
in numerical order (STEP 1 = CAM 1, STEP 2 =
CAM 2, STEP 3 = CAM 3, STEP = 4, CAM 4, STEP 5
= CAM 5…)
PRE: This stands for a camera’s preset position num-
ber. 1 to 64 or "- -" is selectable. When the camera
has no preset position, select "- -". You can set "- -"
by pressing the button 0.
The factory default setting is "- -".
DWELL: This stands for the dwell time. 1 second to 30
seconds are selectable. If you enter 0, the
sequence step will be skipped.
The factory default setting is 2S for each step.
After the configuration, press the MON (ESC) button. The
monitor display will return to the previous menu.
After all the configurations, press the SETUP button while
holding down the SHIFT button. The configuration will be
updated when closing SETUP MENU.
Notes:
•A preset position number is available only when a com-
bination camera is selected for CAM.
• The available preset position numbers differ among
cameras. Refer to each camera's operating instruc-
tions.
■ ALARM SETUP
● How to Display
To display this menu on the monitor, move the cursor to 400
ALARM in SETUP MENU by moving the joystick to ▼ or ▲.
Then, press the CAM (SET) button. The submenu appears
on the monitor.
● Parameters
Move the joystick to move the cursor.
Press the NEXT or PREV button to select the desired para-
meters.
Press the numeric button(s) to enter a number.
• ALARM MODE
You can select an operation mode when alarm input signals
are accepted by the unit.
Notes:
• The alarm mode is activated when alarm input signals
are assigned to the same monitor through 420 ALARM
EVENT or the Alarm Event (refer to p. 74) window.
• While alarm is activated, you cannot operate the func-
tions related to the multiplexer board.
SEQUENCE: An alarm operation is replaced by anoth-
er one after the dwell time (DWELL) ends.
HOLD: An initial alarm operation is continued even after
another alarm input is accepted.
OFF: Select this when not using the alarm mode.
The factory default setting is SEQUENCE.
• DWELL
This stands for the dwell time of a sequence during an
alarm mode.
1 to 30 seconds are selectable.
The factory default setting is 2 seconds.
• ALARM EVENT
This item is configurable in 420 ALARM EVENT.
Move the cursor and press the CAM (SET) button.
420 ALARM EVENT will appear on the monitor.
ALM: This stands for the alarm number.
MON: This stands for the monitor number.
MODE: This stands for the display mode of an alarm
image.
• CAMnn (nn is the camera number): Activates the
spot camera when an alarm input is accepted.
400 ALARM
410 ALARM MODE SEQUENCE
/
DWELL 2sec
420 ALARM EVENT
ALARM INPUT
430 CAMERA OFF
440 ALARM PORT ONO
450 SERIAL PORT ON
460 MUX MOTION DET OFFO
420 ALARM EVENT 1 of 2
ALM MON MODE
1 1 CAM01
/
PRE--
2 1 CAM02
/
PRE--
3 1 CAM03
/
PRE--
4 1 CAM04
/
PRE--
5 1 CAM05
/
PRE--
6 1 CAM06
/
PRE--
7 1 CAM07
/
PRE--
8 1 CAM08
/
PRE--
420 ALARM EVENT 2 of 2
ALM MON MODE
9 1 CAM09
/
PRE--
10 1 CAM10
/
PRE--
11 1 CAM11
/
PRE--
12 1 CAM12
/
PRE--
13 1 CAM13
/
PRE--
14 1 CAM14
/
PRE--
15 1 CAM15
/
PRE--
16 1 CAM16
/
PRE--