45
■ Connection with the Time-lapse VCR (Panasonic Models)
1. Configure the parameters of the multiplexer functions in the Multiplexer Mode (refer to p. 82) window of WJ-SX150
Administrator Console.
Note: When VCR is selected in 610 RECORDER CONTROL in SETUP MENU (refer to p. 60), parameter configuration in the
Multiplexer Mode window is unavailable.
2. Select VCR for 610 RECORDER CONTROL in SETUP MENU. (Refer to p. 60.)
3. Conform the communication speed (COMM. SPEED) for 750 SERIAL PORT SPEED in SETUP MENU to that of the time-
lapse VCR. (Refer to p.61.)
The following parameters are fixed.
Data bit: 7 bits
Parity check: ODD
Stop bit: 1 bit
4. Connect the matrix switcher’s EXT OUT (REC OUT) to the time-lapse VCR’s VIDEO IN with the coaxial cable.
5. Connect the matrix switcher’s EXT IN (PLAY IN) to the time-lapse VCR’s VIDEO OUT with the coaxial cable.
6. Connect the matrix switcher’s SERIAL to that of the time-lapse VCR with a 9-pin D-sub cable.
7. Connect the matrix switcher’s CAMERA SW IN to the time-lapse VCR’s CAMERA SW OUT with an RCA-pin cable.
Notes:
• Only Panasonic time-lapse VCRs which support RS-232C are usable. (Refer to Cable Specifications on the next page
for details of cables.)
• Both of the time-lapse VCR and PC cannot be connected to the matrix switcher.
• When configuring the system through WJ-SX150 Administrator Console, pull out the time-lapse VCR’s cable and con-
nect the PC’s cable to the serial port.
• To use the alarm recording function, connect the matrix switcher’s all alarm output terminals (Alarm Output 1 to 4) to
the time-lapse VCR’s ALARM IN.
• Be sure to activate auto-recovery for the VCR’s alarm reset function.