Panasonic WJ-SX 150 Network Router User Manual


 
63
MUX CAMERA TITLE
How to Display
This menu will appear only when the Multiplexer board is
installed in the unit. To display this menu on the monitor,
move the cursor to 1000 MUX CAMERA TITLE in SETUP
MENU by moving the joystick to D or C. Then, press the
CAM (SET) button. The submenu appears monitor.
How to edit
The factory default settings are same as illustrations.
The editing procedure is the same as 500 CAMERA TITLE.
(Refer to p. 59.)
Notes:
Up to 8 alphanumeric characters are available for
each multiplexer board camera title.
When moving the joystick to D at the last text box
of CAM 8 TITLE, the cursor will move to the first text
box of CAM 9 TITLE.
When moving the joystick to C at the first text box
of CAM 9 TITLE, the cursor will move to the last text
box of CAM 8 TITLE.
1000 MUX CAMERA TITLE
CAM TITLE CAM TITLE
1 C01 9 C09
2 C02 10 C10
3 C03 11 C11
4 C04 12 C12
5 C05 13 C13
6 C06 14 C14
7 C07 15 C15
8 C08 16 C16
Parameters
Move the joystick to move the cursor.
Press the NEXT or PREV button to select the desired para-
meters.
• ALARM
EXT: Select this to gen-lock the unit with the recorder
when an alarm is input to the unit.
002,004 to 128 (field): Select one of these alarm
recording rates if the asynchronous unit is connect-
ed to the unit.
The factory default setting is EXT.
• NORMAL
EXT: Select this to gen-lock the unit during the normal
operation.
002,004 to 255 (field): Select one of these normal
recording rates if the asynchronous unit is connect-
ed to the unit.
The factory default setting is EXT.
• DYNAMIC REC
PRI.: Select this to give recording priority to the camera
channel with the alarm input.
ONLY: Select this to record the images from the alarm-
associated camera channel.
GROUP: Select this to give recording priority to a group
of up to 4 camera channels associated to the alarm
input.
OFF: Select this to deactivate the alarm priority mode.
The factory default setting is OFF.
• DUMMY BLACK
ON: Select this to display the black picture for a cam-
era channel that is not connected to the camera.
OFF: Select this to skip the camera channels that are
not connected to the camera in the sequence/spot
mode.
The factory default setting is ON.
• CAM SW LOSS
ON: Select this to make “SW LOSS” blinking on the
associated monitor when loss of the camera switch-
ing pulse is detected.
OFF: Select this not to make “SW LOSS” appear on the
associated monitor when loss of the camera switch-
ing pulse is detected.
The factory default setting is ON.
Note: If EXT is selected for 910 ALARM/920 NORMAL,
the playback images cannot be displayed on the
monitors which are not connected to the EXT IN
connector. Confirm the images on those which are
connected to the recorder.