Panasonic WJ-SX 150 Network Router User Manual


 
37
Connect non-multiplex type cameras to the CAMERA IN
connectors 1 to 16. For cameras equipped with RS-485
communication facilities, connect the RS-485 cable as fol-
lows.
Check the camera addresses when using RS-485 cameras.
Operations from the system controller will be invalid if the
camera addresses are set improperly.
Use addresses from 1 to 16 for individual cameras.
Do not set the same address for more than one camera
in an RS-485 chain.
Before connecting the RS-485 camera(s) to DATA 1, 2
and/or 3, configure the system through WJ-SX150
Administrator Console.
Connection with the Camera Sites
Connect the data-multiplex type cameras (or camera site
equipment) to the CAMERA IN connectors 1 to 16 on the
matrix switcher's rear panel.
Notes:
Make sure that the cable length is less than 900 m
(3 000 ft) between the camera site and the unit when
using RG-59/U, BELDEN 9259 or equivalent cables.
If you use locally procuring cables, it is important to use
only a data-grade cable, which is suitable for RS-485
communication (shielded 2-wire twisted cable).
When the cable length is extended, cable compensa-
tion is available. (Refer to pp. 60 and 78.)
AUX
Alarm
WJ-SX150 Matrix Switcher
CAMERA
1
1
2
2
3
3
DATA 3 DATA 2
OUT
IN
4
4
5
5
6
6
7
7
8
8
9
9
10
10
16
16
RS485(CAMERA)
DATA 1
24
RS485(CAMERA)
LINE
SELECT
CONNECTIONS