18
● Sequence Mode
In the sequence mode, the unit displays the initial alarm
image on the monitor until the dwell time ends, even when
another alarm input is accepted. When the dwell time ends,
the unit automatically replaces the alarm image with the
next one.
● Hold Mode
In the hold mode, the unit continues to display the initial
alarm image until the alarm reset. With the alarm image on
the monitor, the unit notifies you that more than one alarm
input is accepted with "*" next to "ALARM nn (nn is the
alarm number)."
● Alarm Reset
The built-in timer automatically resets the alarm operation
after the time specified in WJ-SX150 Administrator Console.
After the reset, the monitor displays and the sequence will
return to the state before the alarm input.
Note: When more than one alarm input has been accepted,
only the newest can be reset.
● Alarm Suspension
Even when an alarm signal is input, the system will deacti-
vate the alarm input and the alarm mode.
When the alarm suspension is active, "ALM SUSPENDED"
will appear on the monitor.
● Alarm History Table
This table displays the alarms that have occurred in the
past.
The alarm order, date, time, alarm number and event can
be identified.
Up to 100 item can be reserved, and they are overwritten
from the oldest, after more than 100 item have occurred.
Notes:
• When turning off the unit, all the history will be deleted.
• Alarm history can also be identified on the PC.
● Video Loss History Table
While the unit's power is ON, the video signal loss from a
camera or a recorder can occur by cable disconnection,
etc.
In this case, video loss history will be reserved in the sys-
tem, and this table will display the history.
The loss order, date, time, CAMERA IN number and event
can be identified.
Up to 100 item can be reserved, and they are overwritten
from the oldest, after more than 100 item have occurred.
As well as the video loss history, the date of the loss and
recovery, the camera number and the loss status are dis-
played on the table.
Notes:
• When turning off the unit, all the history will be deleted.
• Alarm history can also be identified on the PC.
■ Timer Event
The built-in timer can automatically start or end the
sequence or spot mode on the specified days, which is
configurable in WJ-SX150 Administrator Console.
The available operations:
Tour sequence and spot mode
The available timer events:
Up to 30
Note: When displaying SETUP MENU while timer event is
operating, the operation will stop.
ALARM HISTORY 1 of 2
NO YYYY/MM/DD HH:MM:SS ALARM EVENT
016 2001/08/21 18:59:08 03 ALARM
015 2001/08/21 18:58:08 03 ACK
014 2001/08/21 18:57:08 03 RESET
013 2001/08/21 18:55:08 07 ALARM
012 2001/08/21 18:54:08 07 ACK
011 2001/08/21 18:53:08 07 RESET
010 2001/08/21 18:53:00 09 ALARM
009 2001/08/21 18:52:08 09 RESET
008 2001/08/21 18:51:08 06 ALARM
007 2001/08/21 18:50:08 06 ACK
VIDEO LOSS HISTORY 1 of 2
NO YYYY/MM/DD HH:MM:SS CH EVENT
012 2001/08/21 18:59:08 03 VIDEO RECOVER
011 2001/08/21 18:58:08 14 VIDEO RECOVER
010 2001/08/21 18:57:08 09 VIDEO LOSS
009 2001/08/21 18:55:08 07 VIDEO LOSS
008 2001/08/21 18:54:08 08 VIDEO LOSS
007 2001/08/21 18:53:08 16 VIDEO LOSS
006 2001/08/21 18:53:00 09 VIDEO LOSS
005 2001/08/21 18:52:08 14 VIDEO LOSS
004 2001/08/21 18:51:08 06 VIDEO LOSS
003 2001/08/21 18:50:08 01 VIDEO RECOVER