Panasonic WJ-SX 150 Network Router User Manual


 
81
Data Port
This window configures the parameters of each data port
(RS485, DATA 1 to 4 and DATA HDR port): the protocol, the
baud rate (communication speed), and the connected
cameras.
How to Display
To display this window, click on the (Data Port) button
in the main window (p. 65).
Parameters
• RS-485 Port Group
Protocol: Select RS485 when an RS-485 camera is
connected to the data port.
Select CU360C when the system controller is con-
nected to the data port.
Select PSD when the system controller is connected
to the DATA 4 port via the PS·Data protocol.
PS·Data mode will appear in the window.
Note: The baud rate of DATA HDR is the same as
that of PSD. When you select PSD for DATA 4,
DATA HDR and its baud rate are displayed in
gray and not configurable. When you select
CU360C for DATA 4, DATA HDR and its baud
rate are configurable.
Baud Rate: Select the desired baud rate (communica-
tion speed). 4800, 9600 or 19200 bps is selectable.
RS485 Camera Daisy (RS-485 Camera Daisy): Select
the number(s) of the camera(s) connected to the
RS-485 daisy chain.
Data 1 to 3 are connectable to either of cameras
and system controllers.
When connecting cameras to these ports, select the
connected camera number(s).
PS·Data mode: This stands for the PS·Data parameters
of the DATA 4 port.
Logout Time: Select the desired operable time
before logout. OFF,10, 20, 30, 60, 90 or 120 sec
is available.
The factory default setting is 30 sec.
Alarm Data: Select the desired time to accept an
alarm input signal. OFF, 0, 1 or 5 sec is avail-
able.
The factory default setting is 1 sec.
Wait Time: Select the desired wait time to transmit
an alarm output signal. OFF, 100msec, 200m
sec, 400m sec or 1 sec is available.
The factory default setting is OFF.
Group Address: This parameter is only for confir-
mation. Leave as it is.
• Fixed Common Parameter Group
The data bit (8 bit), parity (none), and stop bit (1 bit) are
displayed. These parameters are fixed.
(Save Exit) button
Saves the configuration and closes the Data Port window.
(Cancel Exit) button
Cancels the configuration and closes the Data Port window.