Panasonic WJ-SX 150 Network Router User Manual


 
17
Notes:
The images cannot be displayed while cleaning the
camera. Use this function when continuous surveillance
is not necessary, such as after-hours time.
Cameras which are operating or being in the sequence
mode are not cleaned.
Camera selection will immediately stop the camera
cleaning.
If noise remains in the monitor even after the camera
cleaning, there can be a malfunction. Stop using the
camera and consult qualified service personnel.
Alarm-related Functions
This unit is equipped with 16 alarm input connectors. When
an alarm input signal is accepted via one of them, the
alarm-associated spot image or tour sequence image is
displayed on the monitor. With the alarm image on the mon-
itor, the unit notifies you of the alarm information with
"ALARM nn (nn is the alarm number)."
There are two ways to display the alarm-associated image:
Sequence mode
Hold mode
Notes:
The camera (or tour sequence) and monitor need to be
associated with the alarm number through the configu-
ration in SETUP MENU (OSD) or WJ-SX150
Administrator Console.
The mode is selectable and configurable in SETUP
MENU (OSD) or WJ-SX150 Administrator Console.
Even in the alarm mode, pressing the ACK button can
control the camera's pan/tilt, zoom, focus and lens iris.
When a recorder is connected to the matrix switcher,
the alarm-related recording of the camera images is
possible.
External Equipment Control
When the camera is connected via a receiver, the external
equipment connected to the receiver can be controlled.
Controllable Camera-related Functions
The control is conducted while watching the camera
images on the monitor.
Changing to black and white pictures
Camera function (Shortcut function)
Note: The specified cameras can control each function.
Confirm the functions of the connected cameras and
external devices.
Changing to Black and White Pictures
Color images are changeable to black and white images.
This function is intended for surveillance in a dark place
such as an underground parking lot.
Camera Function (Shortcut Function)
The frequently-used functions are registered with the cam-
era function button.
Pressing the button can activate the registered functions.
Refer to the camera's operating instructions for details on
the registered functions.
Camera Title
The titles for camera identification, which are displayed on
the monitor, can be registered.
For example, if a camera setting place is registered as a
camera title, operators can be informed where the image is
recorded.
The title is displayed in one line.
The available character numbers:
20 (camera number and the characters)
The available characters:
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijkl
mnopqrstuvwxyz0123456789!"#$%&'()=+*_:;,. */?
Notes:
Camera title is configurable in SETUP MENU and WJ-
SX150 Administrator Console.
User font characters can be made through WJ-SX150
Administrator Console.
Camera Cleaning
When using a combination camera, noise can occur on the
monitor after the long-term use.
In this case, the camera needs to be cleaned.
Camera cleaning is configurable to be conducted at the
designated day and time.
The cleaning time is approximately 30 seconds per cam-
era.
Time
Alarm
input 1
Alarm
input 5
Alarm
input 2
Alarm
input 1
Alarm
input 5
Alarm
input 2
Alarm reset operations
• Description about sequence mode and hold mode
Camera image
ALARM 01 ALARM 05
ALARM 01 ALARM 05
ALARM 02
Dwell time
Camera image
Sequence
mode
Hold mode
Automatically replaces
the alarm image