50
SETUP PROCEDURES
■ Setup Procedures
This unit has two setting procedures.
The one is SETUP MENU, which is the unit's on-screen dis-
play (OSD).
The other is WJ-SX150 Administrator Console, which oper-
ates on the PC.
• SETUP MENU (OSD)
The basic functions, which are essential for the operation,
are configurable. However, some items are not config-
urable. The settings about group sequences, operators and
schedules, etc.
• WJ-SX150 Administrator Console (PC)
All the functions of this unit are configurable. You need a
PC to use WJ-SX150 Administrator Console.
Refer to p. 64 WJ-SX150 ADMINISTRATOR CONSOLE for
details of the platform and installation.
Notes:
• To use WJ-SX150 Administrator Console, you need to
prepare a PC and a 9-pin D-sub cable.(Refer to p. 47.)
• When changing the configuration of WJ-SX150
Administrator Console, configuration data getting and
putting are necessary between the unit and PC to acti-
vate your configuration.
■ Description of Setup Procedures
This chapter describes about configurable items.
● Sequence Settings
SETUP MENU can configure tour sequences. WJ-SX150
Administrator Console can configure both of tour
sequences and group sequences.
• Tour sequence: Up to 16 tour sequences are config-
urable (16 steps per tour).
• Group sequence: Tour sequences can be activated on
up to 4 monitors simultaneously (1 tour sequence per
monitor).
● Schedule Settings
SETUP MENU can configure daylight saving time. WJ-
SX150 Administrator Console can configure timer event,
camera cleaning, and daylight saving time.
• Timer event: A sequence or spot mode can be activat-
ed on the regular time of every month, week or day.
Up to 30 timer events can be registered.
• Camera cleaning: Camera cleaning can be executed
on the regular time of every month, week or day.
• Daylight saving time: Daylight saving times for 20 years
are configurable.
● Alarm Settings
The operation parameters when an alarm is input to the unit
are configurable.
• Alarm mode: The operation mode activated along with
an alarm input is configurable. Sequence mode or hold
mode is selectable. Alarm mode can be set to OFF
when not using it.
• Alarm event: The event activated along with an alarm
input is assignable to each alarm input terminals. The
sequence number or spot camera is selectable for the
alarm event.
•Alarm input (Alarm port): The alarm polarity (N. O. or N.
C.) is assignable to each alarm input terminal. One of
16 terminals is assignable for time adjustment.
SETUP MENU (OSD)
WJ-SX150 Administrator Console (PC)
Sequence settings
• Tour sequence
• Group sequence
Schedule settings
• Timer event
• Camera cleaning
• Daylight saving time
Alarm settings
• Alarm mode
• Alarm event
• Alarm input/Alarm port
Operator settings
• Operator registration
• Level table
• Monitor select (Monitor selection)
•
Auto login/logout (Auto log-in/log-out)
System settings
• Clock (Time and date) *
1
• Cable compensation
• Camera title
• Data port *
2
Multiplxer board
• Recorder
• Multiplexer *
3
• Mux (Multiplxer camera title) *
3
Setup file operation
• Put a file to SX150
•
Get a configuration data from the SX150
SX150 Admin Console Configuration
• File Open
• Account Manager
• Communication (Serial) port
• Camera manual cleaning ON/OFF
*
1
WJ-SX150 Administrator Console can configure the
display pattern.
*
2
WJ-SX150 Administrator Console can configure the
communication speed (baud rate) of the ports Data 1 to 4.
*
3
These menus (or windows) appear only when the Multiplxer
is installed in the unit.