Paradyne 6800 Switch User Manual


 
COMSPHERE 6800 Series Network Management System
2-142 January 1997 6800-A2-GB31-20
Display Thresholds (dst)
Use the dst command to display the current fault threshold set on COMSPHERE 3400/4400 Series
devices which determine when alerts should be generated. Threshold (TH) alerts are generated
when the line parameters exceed the thresholds defined by the Change Thresholds (cht) command.
For most commands, NMS enables you to specify the destination for the command’s results and
schedule its execution. If the last page of the input form cannot accommodate the Destination for
results and Schedule execution fields, an additional page is provided. For a complete description
of these fields, refer to Chapter 1, Introduction.
Access Level: Help Desk, Data Technician, Manager, System Administrator
Abbreviation: dst
Restrictions: None
Routine: Yes
Schedule: Yes
Related Commands: Change Thresholds (cht)
Display Thresholds Input Form
This input form contains the following field:
Device(s) (Required field)
Enter the device(s) for which thresholds are to be displayed. One or more devices may be
specified. Standard addressing format applies to the input. For information on device
addressing, refer to Appendix D of the COMSPHERE 6800 Series Network Management
System User’s/System Administrator’s Guide.
Display Thresholds Results Form
The Display Thresholds results form lists device information for each device specified, and
displays the threshold information applicable to the device.
This results form contains the following fields:
Receive level (high)
Displays the high received signal level that causes a device to report a threshold alert.
Receive level (low)
Displays the low received signal level that causes a device to report a threshold alert.
Signal-to-noise ratio
Displays a signal-to-noise ratio that, when exceeded, triggers a threshold alert.