Paradyne 6800 Switch User Manual


 
2Modem/DSU Commands
2-1936800-A2-GB31-20 January 1997
Report Terminal Power (rtp)
Use the rtp command to determine if the terminal connected to a data channel on a COMSPHERE
3400/4400 Series modem, a COMSPHERE 3600 Series DSU/DBM, a DATAPHONE II APL
modem or a DATAPHONE II 2700 Series DSU is powered on.
The device checks for a voltage level on its Request-to-Send (RTS) customer interface lead. If a
voltage greater than +5 or less than –5 volts is detected, it reports that the terminal is powered on.
For most commands, NMS enables you to specify the destination for the command’s results and
schedule its execution. If the last page of the input form cannot accommodate the Destination for
results and Schedule execution fields, an additional page is provided. For a complete description
of these fields, refer to Chapter 1, Introduction.
Access Level: Help Desk, Data Technician, Manager, System Administrator
Abbreviation: rtp
Restrictions: None
Routine: Yes
Schedule: Yes
Related Commands: None
Report Terminal Power Input Form
This input form contains the following fields:
Device(s) (Required field)
Enter the device(s) to be involved in this test. One or more devices may be specified.
Standard addressing format applies to the input. For information on device addressing,
refer to Appendix D of the COMSPHERE 6800 Series Network Management System
User’s/System Administrator’s Guide.
Port number (Required field)
Specify the port number for which terminal power should be checked.
For 3400/4400 Series modems, valid entries are from 1 through 4.
For 3600 Series DSUs and DATAPHONE II devices, the only valid entry is 1.
A pop-up menu is available listing valid selections. The default is 1.
Report Terminal Power Results Form
This results form displays device information for each device tested, the requested port number,
and the terminal power state (on or off) for the requested port.