Paradyne 6800 Switch User Manual


 
COMSPHERE 6800 Series Network Management System
2-32 January 1997 6800-A2-GB31-20
Call Test (ct)
Use the ct command to cause a COMSPHERE 3400/4400 Series modem with a DBM to initiate a
call test using either the telephone number or directory entry specified. Once the proprietary tones
are validated at the remote end, the test completes by disconnecting the dial line. Leased-line
operation is not interrupted by this test.
For a 3900 Series modem, three different requests can be performed to initiate a call test. These
tests are invoked by using a new field which appears on the input form when 3900 Series device
addresses are specified in the device field.
For most commands, NMS enables you to specify the destination for the command’s results and
schedule its execution. If the last page of the input form cannot accommodate the Destination for
results and Schedule execution fields, an additional page is provided. For a complete description
of these fields, refer to Chapter 1, Introduction.
Access Level: Data Technician, Manager, System Administrator
Abbreviation: ct
Restrictions: None
Routine: Yes
Schedule: Yes
Related Commands: Standby Facility (sf)
Call Test Input Form
The Call Test input form contains the following fields:
Device(s) (Required field)
Enter the device(s) for which the call test is to be performed. Multiple devices can be
specified. Standard addressing format applies to the input. For information on device
addressing, refer to Appendix D of the COMSPHERE 6800 Series Network Management
System User’s/System Administrator’s Guide.
Number to dial (Required field)
Enter the telephone number to be dialed, or a directory whose number should be used. See
the Change Call Directory (chcd) command for a list of valid dialing characters for the
3400/4400 Series modem with a DBM. See the Dial (dial) command for valid entry
formats.