Chapter 1 Getting Started
© Polycom, Inc. 7 ViewStation User Guide
Once the interface is properly connected, the ViewStation 128 is
ready to be configured for Ethernet LAN connectivity. See
“Connecting the ViewStation to an Ethernet LAN," on page 8.
Connecting the ViewStation H.323 with V.35 to a Network
The ViewStation H.323 with V.35 uses a Polycom V.35 network
interface module and has two HD-25 female ports (labeled 1 and 2)
that are used to connect to your Data Communications Equipment
(DCE).
Note Cable diagrams and pinout schematics are located in V.35
Technical Information," on page 193.
Connecting the V.35 Network Interface Module to the
ViewStation
Complete the following steps to connect the V.35 network interface
module to the ViewStation:
1. Connect the green-tipped RJ-45 cable to the green RJ-45 port
on the back of the ViewStation.
2. Insert the opposite end of the green-tipped RJ-45 cable to the
port labeled
xon the network interface module.
Connecting the V.35 Network Interface Module to the V.35
DCE
Complete the following steps to connect the V.35 network interface
module to the V.35 DCE:
1. Connect the male HD-25 cable ends to ports 1 and 2 on the
network interface module. If you want to connect only one cable,
connect to port 1 on the interface module.
Connector screws should be lightly snug, not tight.
2. Connect the remaining cable ends to the DCE V.35/RS-449 port
and the DB-25/RS-366 dialing port, if used. If connecting one
cable only, connect to the lowest ordered port on the DCE.