Renesas M16C/64 Network Card User Manual


 
R0E530640MCU00 User’s Manual 5. Debugging Functions
REJ10J1733-0100 Rev.1.00 Apr. 01, 2008
Page 164 of 229
5.11.14 Clearing Code Coverage Information
(1) Clearing a specified range of code coverage information
Choose Clear Coverage Range from the context menu, and the Clear Address Range dialog box shown below will be displayed.
Figure 5.95 Clear Address Range dialog box
Specify the start and end address of the range you want to clear.
Click the OK button, and the specified range will be cleared.
(2) Clearing all code coverage information
Choose Clear the Entire Coverage from the context menu, and all code coverage information will be cleared.
5.11.15 Updating Coverage Information
Update the content of the Code Coverage window to the latest. Choose Refresh from the context menu of the Code Coverage
window.
If the coverage information is inhibited from getting updated, the information is not automatically updated when the program
breaks. To view the latest information, therefore, you need to update manually.
5.11.16 Inhibiting Updating of Information
The content of the Code Coverage window is not updated when, for example, the user program has stopped running. Choose
Lock Refresh from the context menu of the Code Coverage window.