Blade ICE G8124-E Personal Computer User Manual


 
BLADEOS 6.5.2 Application Guide
BMD00220, October 2010 Chapter 13: VMready 175
Pre-Provisioning VEs
VEs may be manually added to VM groups in advance of being detected on the switch ports. By
pre-provisioning the MAC address of VEs that are not yet active, the switch will be able to later
recognize the VE when it becomes active on a switch port, and immediately assign the proper VM
group properties without further configuration.
Undiscovered VEs are added to or removed from VM groups using the following configuration
commands:
For the pre-provisioning of undiscovered VEs, a MAC address is required. Other identifying
properties, such as IPv4 address or VM name permitted for known VEs, cannot be used for
pre-provisioning.
Note – Because VM groups are isolated from vNIC groups (see “vNIC Groups” on page 157),
pre-provisioned VEs that appear on vNIC ports will not be added to the specified VM group upon
discovery.
RS G8124(config)# [no] virt vmgroup <VM group number> vm <VE MAC address>