Blade ICE G8124-E Personal Computer User Manual


 
BLADEOS 6.5.2 Application Guide
372 Chapter 27: Remote Monitoring BMD00220, October 2010
Configuring RMON History
Perform the following steps to configure RMON History on a port.
1. Enable RMON on a port.
2. Configure the RMON History parameters for a port.
where <x> is the number of the port to monitor. For example, the full OID for port 1 would be:
1.3.6.1.2.1.2.2.1.1.1
3. View RMON history for the port.
RS G8124(config)# interface port 1
RS G8124(config-if)# rmon
RS G8124(config-if)# exit
RS G8124(config)# rmon history 1 interface-oid 1.3.6.1.2.1.2.2.1.1.<x>
RS G8124(config)# rmon history 1 requested-buckets 30
RS G8124(config)# rmon history 1 polling-interval 120
RS G8124(config)# rmon history 1 owner "rmon port 1 history"
RS G8124(config)# show rmon history
RMON History group configuration:
Index IFOID Interval Rbnum Gbnum
----- ----------------------- -------- ----- -----
1 1.3.6.1.2.1.2.2.1.1.1 120 30 30
Index Owner
----- ----------------------------------------------
1 rmon port 1 history