Cisco Systems ONS 15327 Switch User Manual


 
1-29
Cisco ONS 15327 Troubleshooting Guide, R3.4
April 2003
Chapter 1 General Troubleshooting
Identify Points of Failure on an OC-N Circuit Path
Step 4 If the test set indicates a faulty circuit, the problem might be a faulty card.
Step 5 Proceed to the “Test the OC-N Card” procedure on page 1-29.
Procedure: Test the OC-N Card
Step 1 Replace the suspect card with a card known to be good. See the “Physically Replace a Card” procedure
on page 2-130 for details.
Step 2 Resend test traffic on the loopback circuit with a good card.
Step 3 If the test set indicates a good circuit, the problem is probably the defective card:
a. Return the defective card to Cisco through the returned materials authorization (RMA) process.
Contact the Cisco TAC.
b. Replace the defective OC-N card. See the “Physically Replace a Card” procedure on page 2-130 for
details.
c. Clear the terminal loopback before testing the next segment of the network circuit path:
Double-click the OC-N card in the source node with the terminal loopback.
Click the Maintenance > Loopback tabs.
Select None from the Loopback Type column for the port being tested.
Select the appropriate state (IS, OOS, or OOS_AINS) in the State column for the port being
tested.
Click the Apply button.
Click the Yes button in the Confirmation Dialog box.
d. Clear the terminal loopback circuit before testing the next segment of the network circuit path:
Click the Circuits tab.
Choose the loopback circuit being tested.
Click the Delete button.
Click the Yes button in the Delete Circuits dialog box.
Step 4 Proceed to the “1.3.4 Perform a Facility Loopback on an Intermediate-Node OC-N Port” section on
page 1-29.
1.3.4 Perform a Facility Loopback on an Intermediate-Node OC-N Port
The facility loopback test is performed on the node source port in the network circuit, in this example,
the source OC-N port in the intermediate node. Completing a successful facility loopback on this port
isolates the OC-N port as a possible failure point. Figure 1-15 on page 1-30 shows an example of a
facility loopback on a intermediate node circuit source OC-N port.