Dell MXL 10/40GbE Switch User Manual


  Open as PDF
of 1094
 
When you apply an FCoE map on a fabric-facing FC port, the FC port becomes part of the FCoE fabric,
whose settings in the FCoE map are configured on the port and exported to downstream server CNA
ports.
Each MXL 10/40GbE Switch and M I/O Aggregator, with the FC Flex IO module FC port, is associated with
an Ethernet MAC address (FCF MAC address). When you enable a fabric-facing FC port, the FCoE map
applied to the port starts sending FIP multicast advertisements using the parameters in the FCoE map
over server-facing Ethernet ports. A server sees the FC port, with its applied FCoE map, as an FCF port.
Step Task Command Command Mode
1
Configure a fabric-facing FC port.
interface
fibrechannel slot/
port
CONFIGURATION
2
Apply the FCoE and FC fabric configurations in
an FCoE map to the port. Repeat this step to
apply an FCoE map to more than one FC port,
for example:
Dell# interface fi 0/0Dell(config-
if-fc-0/0)# fabric SAN_FABRIC_A
fabric
map-name
INTERFACE
FIBRE_CHANNEL
3
Enable the port for FC transmission.
no shutdown
INTERFACE
FIBRE_CHANNEL
Tip: You can apply a DCB or FCoE map to a range of Ethernet or Fibre Channel interfaces by using
theinterface range command; for example:
Dell(config)# interface range tengigabitEthernet 1/12 - 23 , tengigabitEthernet
2/24 - 35
Dell(config)# interface range fibrechannel 0/0 - 3 , fibrechannel 0/8 - 11
Enter the keywords interface range followed by an interface type and port range. A port range must
contain spaces before and after the dash. Separate each interface type and port range with a space,
comma, and space as shown in the preceding examples.
Sample Configuration
1. Configure a DCB map with PFC and ETS settings:
Dell(config)# dcb-map SAN_DCB_MAP
Dell(config-dcbx-name)# priority-group 0 bandwidth 60 pfc off
Dell(config-dcbx-name)# priority-group 1 bandwidth 20 pfc on
Dell(config-dcbx-name)# priority-group 2 bandwidth 20 pfc on
Dell(config-dcbx-name)# priority-group 4 strict-priority pfc off
Dell(conf-dcbx-name)# priority-pgid 0 0 0 1 2 4 4 4
2. Apply the DCB map on a downstream (server-facing) Ethernet port:
FC Flex IO Modules