Managing firmware versions Testing firmware before upgrading
FortiAnalyzer Version 3.0 MR7 Administration Guide
05-30007-0082-20080908 173
8 Type G to get the new firmware image from the TFTP server.
The following message appears:
Enter TFTP server address [192.168.1.168]:
9 Type the address of the TFTP server and press Enter.
The following message appears:
Enter Local Address [192.168.1.188]:
10 Type the internal IP address of the FortiAnalyzer unit.
This IP address connects the FortiAnalyzer unit to the TFTP server. This IP
address must be on the same network as the TFTP server, but make sure you do
not use an IP address of another device on the network.
The following message appears:
Enter firmware image file name [image.out]:
11 Enter the firmware image file name and press Enter.
The TFTP server uploads the firmware image file to the FortiAnalyzer unit and the
following appears:
Save as Default firmware/Backup firmware/Run image without
saving: [D/B/R]
12 Type R.
The FortiAnalyzer firmware image installs and saves to system memory. The
FortiAnalyzer unit starts running the new firmware image with the current
configuration.
When you are done testing the firmware, you can reboot the FortiAnalyzer unit
and resume using the original firmware. You will need to restore the original
configuration file after the testing.