HP (Hewlett-Packard) HP FAX-900 Fax Machine User Manual


 
Problem Resolution5Ć22
Table 5-2. HP FAX-700 and FAX-750 Service Parameters (Continued)
Service
Parameter
Number
Display
Indication
Parameter
Description
Settings Current
Setting
Standard
Setting
17 NOT USED
18 MINIMUM ON-
HOOK
Minimum time the ma-
chine goes on-hook be-
tween sending consecu-
tive faxes. If this time
were too short the local
CO might not see the
“on-hook and not pro-
duce a dial tone
0...15 SEC 5 5
19 RESPONSE
WAIT
Duration of the wait for a
response from the re-
mote station
0...90 SEC 55 55
20 PAUSE TIME Duration of a pause
created by pressing the
Space button
0...10 SEC 3 3
21 BUSY TONE
COUNT
Selects the number of
busy tones detected be-
fore recognition by the
machine that the remote
party is busy
0...10 TIMES 2 2
22 BUSY TONE
DETECT
This specifies whether
the machine will attempt
to detect a busy signal
after dialing. If “on”, the
machine will go back on
hook if it detects a busy
signal
0:off* / 1:on 0 0
23 DIAL TONE
DETECT
Selects whether or not
the fax machine will de-
tect a dial tone
0:off* / 1:on 0 0
24 LIU TYPE Selects the type of line
interface unit the fax ma-
chine has
01: US 02: not US* 2 2
25 NOT USED
26 MIN MEM TO
RCV
Selects the minimum
percent memory the fax
machine must have avail-
able in order to receive a
fax
0...99% 10 10
27 SILENT
DETECT DLY
Selects the delay before
detecting machines that
do not respond with a
CNG signal (old fax ma-
chines)
0...99 SEC 20 20
28 SILENT
DETECT TO
This is the time from
completing dialing to
when silent detect is
switched off
0...99 SEC 60 60