Hitachi SJ300 Series Power Supply User Manual


 
SJ300 Inverter
Configuring Drive
Parameters
3–35
NOTE: Two sets of overload restriction parameters are available. The set that is in use may be
selected by means of an intelligent input terminal (see Overload Restriction” on page 4–35).
B025 Overload restriction
setting (2)
Sets the level for overload
restriction (2), between 50%
and 200% of the rated
current of the inverter,
setting resolution is 1% of
rated current
✘ ✔ rated current times
1.50
A
>b025 OLOAD
2LEVEL 0024.8A
B026 Deceleration rate at
overload restriction (2)
Sets the deceleration rate (2)
when inverter detects
overload, range is 0.1 to
30.0, resolution is 0.1.
✘ ✔ 1.00 1.00 1.00 sec.
>b026 OLOAD
2CONST 01.00
“B” Function
Run
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name Description
–FE
(EU)
–FU
(US)
–FR
(JP)