Hitachi SJ300 Series Power Supply User Manual


 
SJ300 Inverter
Appendix C
C–3
Standard
Functions
“A” Group Parameters Default Setting
User
Setting
Func.
Code
Name
-FE (Europe) -FU (U.S.) -FR (Japan)
A001 Frequency source setting 01 01 02
A002 Run command source setting 01 01 02
A003 Base frequency setting 50. 60. 60.
A203 Base frequency setting, 2nd motor 50. 60. 60.
A303 Base frequency setting, 3rd motor 50. 60. 60.
A004 Maximum frequency setting 50. 60. 60.
A204 Maximum frequency setting, 2nd
motor
50. 60. 60.
A304 Maximum frequency setting, 3rd
motor
50. 60. 60.
A005 [AT] selection 00 00 00
A006 [O2] selection 03 03 03
A011 [O]–[L] input active range start
frequency
0.00 0.00 0.00
A012 [O]–[L] input active range end
frequency
0.00 0.00 0.00
A013 [O]–[L] input active range start
voltage
0. 0. 0.
A014 [O]–[L] input active range end
voltage
100. 100. 100.
A015 [O]–[L] input start frequency enable 01 01 01
A016 External frequency filter time const. 8. 8. 8.
A019 Multi-speed operation selection 00 00 00
A020 Multi-speed frequency setting 0.00 0.00 0.00
A220 Multi-speed frequency setting, 2nd
motor
0.00 0.00 0.00
A320 Multi-speed frequency setting, 3rd
motor
0.00 0.00 0.00
A021 Multi-speed 1 setting 0.00 0.00 0.00
A022 Multi-speed 2 setting 0.00 0.00 0.00
A023 Multi-speed 3 setting 0.00 0.00 0.00
A024 Multi-speed 4 setting 0.00 0.00 0.00
A025 Multi-speed 5 setting 0.00 0.00 0.00
A026 Multi-speed 6 setting 0.00 0.00 0.00
A027 Multi-speed 7 setting 0.00 0.00 0.00