Hitachi SJ300 Series Power Supply User Manual


 
Introduction
Motor Control
Accessories
5–2
Introduction
A motor speed control system will obviously include a motor and inverter, as well as fuses for
safety. If you are connecting a motor to the inverter on a test bench just to get started, that’s all
you may need for now. But a fully developed system can also have a variety of additional
components. Some can be for noise suppression, while others may enhance the inverter’s
braking performance. The figure below shows a system with several possible optional compo-
nents, and the table gives part number information.
AC reactor, or
LCR filter
RF noise
filter
DC link choke
AC reactor
EMI filter
Capacitive filter
Braking
resistor
Braking
unit
RF noise filter
Thermal switch
NOTE: The Hitachi part number series for accessories
includes different sizes of each part type, specified by the
–x suffix. Hitachi product literature can help match size
and rating of your inverter to the proper accessory size.
Each inverter accessory comes with its own printed
instruction manual. Please refer to those manuals for
complete installation details. This chapter gives only an
overview of these optional system devices. For more infor-
mation on Hitachi inverter system accessories, please
contact your Hitachi sales office or distributor.
Name
Part No. Series
See
page
Europe,
Japan
USA
AC reactor, input
side
ALI–xxx HRL–x 5–3
RF noise filter,
input side
ZCL–x ZCL–x 5–4
EMI filter
(EMC Class A)
NF–CEHx NF–CEHxx 5–4
EMI filter
(EMC Class B)
NF–CEHx,
with FC–Hx
NF–CEHxx,
with FC–Hx
5–4
Capacitive filter CFI–x CFI–x 5–4
DC link choke
HDC–xxx 5–4
Braking resistor JRB–xxx–x,
SRB–xxx–x
JRB–xxx,
SRB–xxx
5–9
Braking resistor,
NEMA-rated
HRB1-x,
HRB2-x
HRB3-x
5–9
Resistance braking
unit
BRD–xxx BRD–xxx 5–8
RF noise filter,
output side
ZCL–xxx ZCL–xxx 5–4
AC reactor, output
side
ALI–xxx HRL–xxx 5–3
LCR filter
HRL–xxxC 5–3
Encoder feed-back
expansion
SJ-FB 5–5
Digital input
expansion card
SJ-DG 5–5
Inverter
Encoder input
expansion card
Digital input
expansion card
A B
Switch
Breaker,
MCCB or
GFI
Ferrite core
Expansion bay
L1 L2 L3
T1 T2 T3
Motor
Encoder
RST
+1
+
RB
GND
UVW
From power supply