Hitachi SJ300 Series Power Supply User Manual


 
SJ300 Inverter
Configuring Drive
Parameters
3–63
“H” Function
Run
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name Description
–FE
(EU)
–FU
(US)
–FR
(JP)
H203 Motor capacity, 2nd
setting
Select 0.2 to 75.0kW for
models up to –550xxx,
0.2 to 160.0kW for models
–750xxx to –1500xxx
✘ ✘ Factory set kW
>H203 2AUX
K 003.70kW
H004 Motor poles setting, 1st
motor
Four selections:
2 / 4 / 6 / 8
✘ ✘ 444Poles
>H004 AUX
P 4P
H204 Motor poles setting, 2nd
motor
Four selections:
2 / 4 / 6 / 8
✘ ✘ 444Poles
>H204 2AUX
P 4P
H005 Motor speed constant,
1st motor
Motor proportional gain
constant (factory set),
range is 0.01 to 99
✔ ✔
1.590 1.590 1.590
>H005 AUX
KP 1.590
H205 Motor speed constant,
2nd motor
Motor proportional gain
constant (factory set)
range is 0 to 99
✔ ✔
1.590 1.590 1.590
>H205 2AUX
KP 1.590
H006 Motor stabilization
constant, 1st motor
Motor constant (factory set),
range is 0 to 255
✔ ✔ 100. 100. 100.
>H006 AUX
KCD 00100
H206 Motor stabilization
constant, 2nd motor
Motor constant (factory set),
range is 0 to 255
✔ ✔ 100. 100. 100.
>H206 2AUX
KCD 00100
H306 Motor stabilization
constant, 3rd motor
Motor constant (factory set),
range is 0 to 255
✔ ✔ 100. 100. 100.
>H306 3AUX
KCD 00100
H020 Motor constant R1, 1st
motor
Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53
✘ ✘ According to
inverter rating
Ohm
>H020 AUX
R1 00.489ohm
H220 Motor constant R1, 2nd
motor
Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53
✘ ✘ According to
inverter rating
Ohm
>H220 2AUX
R1 00.000ohm
H021 Motor constant R2, 1st
motor
Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53
✘ ✘ According to
inverter rating
Ohm
>H021 AUX
R2 00.355ohm
H221 Motor constant R2, 2nd
motor
Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53
✘ ✘ According to
inverter rating
Ohm
>H221 2AUX
R2 00.355ohm
H022 Motor constant L, 1st
motor
Range is 0.00 - 655.3 mH,
0.00 to 99.99
100.0 - 655.3
✘ ✘ According to
inverter rating
mH
>H022 AUX
L 005.12mH
H222 Motor constant L, 2nd
motor
Range is 0.00 - 655.3 mH,
0.00 to 99.99
100.0 - 655.3
✘ ✘ According to
inverter rating
mH
>H222 2AUX
L 005.12mH
H023 Motor constant I
0
, 1st
motor
Range is 0.00 to 655.3 A
0.00 to 99.99
100.0 - 655.3
✘ ✘ According to
inverter rating
A
>H023 AUX
I0 008.02A
H223 Motor constant I
0
, 2nd
motor
Range is 0.00 to 655.3 A,
0.00 to 99.99
100.0 - 655.3
✘ ✘ According to
inverter rating
A
>H223 2AUX
I0 008.02A
H024 Motor Constant J, 1st
motor
Ratio (unit-less), range is
1.0 to 1000
✘ ✘ According to
inverter rating
>H024 AUX
J 000.055