The following table pertains to the brake confirmation input.
B123 Brake wait time
for stopping
0.00 to 5.00 sec. Sets the time delay after brake confirmation signal
[BOK] turns OFF (after [BRK] turns OFF) until
decelerating the inverter to 0 Hz
B124 Brake wait time
for confirmation
0.00 to 5.00 sec. Sets the wait time for [BOK] signal after turn ON/
OFF of [BRK] signal. If [BOK] is not received
during the specified time, the inverter will trip with
an external brake error [BER].
B125 Break release
frequency setting
0.00 to 99.99 Hz /
100.0 to 400.0 Hz
Sets the frequency at which the inverter outputs the
brake release signal [BRK] after delay set by B121
B126 Brake release
current setting
0% to 200% of
rated current
Sets the minimum inverter current level above
which the brake release signal [BRK] will be
permitted
Code Function Data or Range Description
Output
frequency
Run command
Brake release output [BRK]
Brake OK input [BOK]
B122 B123
B121
B125 B125
B124
Brake release
frequency
Brake wait time to release
Brake wait time for accel Brake wait time for stop-
Brake wait time
for confirmation
B124
Brake error output [BER]
t
0
Opt.
Code
Symbol Function Name
Input
State
Description
44 BOK Brake confirmation ON Indicates external brake is not engaged
OFF Indicates external brake is engaged
Valid for inputs:
C001, C002, C003, C004,
C005, C006, C007, C008
Required
settings:
B120=01
B121 to B126 set
Notes:
The signal [BOK] turns ON to indicate that an
external brake system has released. If external
brake control is enabled (B120=01), then the
[BOK] signal must work properly to avoid an
inverter trip event.
If [BOK] is not assigned to an intelligent
input, then setting B124 is ignored.
5 3 1
7 6 4 2
8
FW
TH
PLC
CM1
P24
CM1
See I/O specs on page 4–9.
Example: (Requires input configuration—
see page 3–47
. Jumper position shown is
for –xFU/-xFR models; for –xFE models,
see page 4–12
.)
BOK