Hitachi SJ300 Series Power Supply User Manual


 
SJ300 Inverter Specifications
Geting Started
1–6
SJ300 Inverter Specifications
Tables for 200V
class inverters
Note that General Specifications” on page 1–9 covers all SJ300 inverters, followed by
footnotes for all specifications tables. The 200V models in the upper table below (1/2 to 15 hp)
include internal dynamic braking units (see
Dynamic Braking” on page 5–6).
Item 200V Class Specifications
SJ300, 200V models, U.S. version 004LFU 007LFU 015LFU 022LFU 037LFU 055LFU 075LFU 110LFU
Applicable motor size, 4-pole *2 HP 1/2 1 2 3 5 7.5 10 15
kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11
Rated capacity (200/240V) kVA 1.0 / 1.2 1.7 / 2.0 2.5 / 3.1 3.6 / 4.3 5.7 / 6.8 8.3 / 9.9 11 / 13.3 15.9/
19.1
Rated input voltage 3-phase: 200 to 240V ±10%, 50/60 Hz ±5%
Rated input current (A) 3.8 5.5 8.3 12 18 26 35 51
Rated output voltage *3 3-phase (3-wire) 200 to 240V (corresponding to input voltage)
Rated output current (A) 3.0 5.0 7.5 10.5 16.5 24 32 46
Efficiency at 100% rated output, % 85.1 89.5 92.3 93.2 94.0 94.4 94.6 94.8
Watt loss,
approximate (W)
at 70% output 64 76 102 127 179 242 312 435
at 100% output 70 88 125 160 235 325 425 600
Starting torque *6 200% at 0.5 Hz (SLV), 150% at around 0 Hz (SLV, 0 Hz domain,
with motor one frame size down), 100% at 0 Hz (with feedback board)
Dynamic braking
approx. % torque,
short time stop *7
internal res. only 50% 20% 10%
with external res. 200% 160% 100% 80% 70%
DC braking Variable operating frequency, time, and braking force
Weight kg / lb 3.5 / 7.7 3.5 / 7.7 3.5 / 7.7 3.5 / 7.7 3.5 / 7.7 3.5 / 7.7 5 / 11 5 / 11
Item 200V Class Specifications, continued
SJ300, 200V models, U.S. version 150LFU 185LFU 220LFU 300LFU 370LFU 450LFU 550LFU
Applicable motor size *2 HP 20 25 30 40 50 60 75
kW 15 18.5 22 30 37 45 55
Rated capacity (200/240V) kVA 22.1 / 26.6 26.3 / 31.5 32.9 / 39.4 41.9 / 50.2 50.2/60.2 63 / 75.6 76.2/91.4
Rated input voltage 3-phase: 200 to 240V ±10%, 50/60 Hz ±5%
Rated input current (A) 70 84 105 133 160 200 242
Rated output voltage *3 3-phase (3-wire) 200 to 240V (corresponding to input voltage)
Rated output current (A) 64 76 95 121 145 182 220
Efficiency at 100% rated output, % 94.9 95.0 95.0 95.1 95.1 95.1 95.1
Watt loss,
approximate (W)
at 70% output 575 698 820 1100 1345 1625 1975
at 100% output 800 975 1150 1550 1900 2300 2800
Starting torque *6 200% at 0.5 Hz (SLV), 150% at around 0 Hz (SLV, 0 Hz domain,
with motor one frame size down), 100% at 0 Hz (with feedback board)
Dynamic braking
approx. % torque,
short time stop *7
w/o braking unit 10%
with braking unit 30–200% 25–170% 25–150% 55–110% 45–90% 35–75% 30–60%
DC braking Variable operating frequency, time, and braking force
Weight kg / lb 12 / 26.4 12 / 26.4 12 / 26.4 20 / 44 30 / 66 30 / 66 50 / 110