Hitachi SJ300 Series Power Supply User Manual


 
SJ300 Inverter
Operations
and Monitoring
4–47
Output Deviation
for PID Control
The PID loop error is defined as the
magnitude (absolute value) of the differ-
ence between the Setpoint (target value)
and the Process Variable (actual value).
When the error magnitude exceeds the
preset value for C044, the [OD] terminal
signal turns ON. Refer to
PID Loop
Operation” on page 4–71.
NOTE: The example circuit in the table above drives a relay coil. Note the use of a diode to
prevent the negative-going turn-off spike generated by the coil from damaging the inverter’s
output transistor.
Opt.
Code
Symbol Function Name
Output
State
Description
04 OD Output deviation
for PID control
ON when PID error is more than the set
threshold for the deviation signal
OFF when PID error is less than the set thresh-
old for the deviation signal
Valid for
outputs:
11, 12, 13, 14, 15,
AL0 – AL2
Required
settings:
C044
Notes:
The default deviation value is set to 3%. To
change this value, change parameter C044
(deviation level).
Set
value
[OD]
Signal
Error
(SP-PV)
C044
C044
ON ON
t
Process variable
Setpoint
RY
+
See I/O specs on page 4–9.
Inverter output terminal circuit
CM2
1314
15
11
12
Example: (Requires output configuration—
see page 3–53
):
OD